Subscribe to news


Follow us on twitter.


 

LEED

LEED is an internationally recognized green building certification system, providing third-party verification that a building or community was designed and built using strategies aimed at improving performance across all the metrics that matter most: energy savings, water efficiency, CO2 emissions reduction, improved indoor environmental quality, and stewardship of resources and sensitivity to their impacts.

Developed by the U.S. Green Building Council (USGBC), LEED provides building owners and operators a concise framework for identifying and implementing practical and measurable green building design, construction, operations and maintenance solutions
Contribution of Multidomo Metering® for LEED®EB-O&M certification

LEED®EB-O&M certifies that the work of operation and maintenance of the building are being sustainably. Multidomo Metering® contributes and can help you get up to 3 LEED® prerequisites that are required and between 15 and 50 LEED® points from 110 volunteers of LEED® (14%-45%), collecting data and providing information of different measurements (consumption, temperature, air quality).

Credit          

Min. Points

Max. Points

How

SS Credit 6: Stormwater Quantity Control

1

1

Measure, monitor, register, analyze data: rain and re-use

WE Prerequisite 1: Minimum Indoor Plumbing Fixture and Fitting Efficiency

R

R

Measure, monitor, register, and analyze data consumption: taps, sanitary, urinary, showers, batteries and landfills.

WE Credit 1: Water Performance Measurement

1

2

Measure, monitor, register, and analyze data consumption: garden irrigation, equipment and systems plumbing, cooling towers, hot water, process water. Total of the building and plot

WE Credit 4: Cooling Tower Water Management

1

2

Measure, monitor, register, analyze data: drip rates and disinfectants concentration, replenishment not potable water quantities

EA Prerequisite 1: Energy Efficiency Best Management Practices—Planning,

Documentation and Opportunity Assessment

R

R

Measure, monitor, register, analyze data: ASHRAE level I energy audit

EA Prerequisite 2: Minimum Energy Efficiency Performance

R

R

Measure, monitor, register, and analyze data: every building energy use. 12 months continuous measuring.

EA Credit 1: Optimize Energy Efficiency Performance

1

18

Measure, monitor, register, and analyze data: every building energy use. 12 months continuous measuring.

EA Credit 2.1: Existing Building Commissioning—Investigation and Analysis

2

2

Analysis and energy data use classification. Measure, record, and analyze data for energy auditing ASHRAE level II.

EA Credit 2.3: Existing Building Commissioning—Ongoing Commissioning

2

2

Measure, monitor, register, analyze data: systematic efficiency measurements and efficiency deviations

EA Credit 3.2: Performance Measurement—System-Level Metering

1

2

Measure, monitor, register, analyze data: permanently 40% - 80% total consumption for 2 years and for different building energy uses (mechanical systems and other uses)

EA Credit 4: On-site and Off-site Renewable Energy

1

16

Measure, monitor, register, analyze data: renewable energy produced or purchased by the building

EA Credit 6: Emissions Reduction Reporting

1

1

Measure, monitor, register, analyze data: reductions in emissions by renewable and energy efficiency

IE Q Credit 1.1: Indoor Air Quality Best Management Practices—Indoor Air Quality Management Program

1

1

Measure, monitor, register, analyze data: indoor air quality for CAI program

IE Q Credit 1.2: Indoor Air Quality Best Management Practices—Outdoor Air

Delivery Monitoring

1

1

Measure, monitor, register, and analyze data: CO2 sensor network.

IE Q Credit 1.3: Indoor Air Quality Best Management Practices—Increased

Ventilation

1

1

Measure, monitor, register, analyze data: room by room fresh air ventilation rates are met

IE Q Credit 2.3: Occupant Comfort—Thermal Comfort Monitoring

1

1

Measure, monitor, register, analyze data: temperature, humidity, speed air, radiant temperature, alarms, problem identification

 

Contribution of Multidomo Metering® for LEED®NC and LEED®CI

LEED®NC and LEED®CI, certify respectively the buildings in new plant and great remodeling and the second indoor deployments whether new or renovations to existing buildings. Multidomo Metering® contributes and can help you get up to 2 LEED® prerequisites that are required and between 19 and 47 LEED® points from 110 volunteers of LEED® (14%-45%), collecting data and providing information of different measurements (consumption, temperature, air quality).

Credit          

Min. Points

Max. Points

How

SS Credit 6.1: Stormwater Design—Quantity Control

1

1

Measure, monitor, register, analyze data: rain and re-use

SS Credit 6.2: Stormwater Design—Quality Control

1

1

Measure, monitor, register, analyze data: water filtration from rain and re-use

WE Prerequisite 1: Water Use Reduction

R

R

Measure, monitor, register, and analyze data consumption: taps, sanitary, urinary, showers, batteries and landfills.

WE Credit 1: Water Efficient Landscaping

2

4

Measure, monitor, register, and analyze data consumption: garden irrigation.

WE Credit 2: Innovative Wastewater Technologies

2

2

Measure, monitor, register, analyze data: issued waste water and filter parameters

WE Credit 3: Water Use Reduction

2

4

Measure, monitor, register, and analyze data consumption: taps, sanitary, urinary, showers, batteries and landfills.

EA Prerequisite 2: Minimum Energy Performance

R

R

Measure, monitor, register, and analyze data: every building energy use. 12 months continuous measuring.

EA Credit 1: Optimize Energy Performance

1

19

Measure, monitor, register, and analyze data: every building energy use. 12 months continuous measuring.

EA Credit 4: Green Power

1

7

Measure, monitor, register, analyze data: renewable energy produced or purchased by the building

EA Credit 5: Measurement and Verification

3

3

Measure, follow, register, analyze data: 10 parameters IPMVP one year of operation

IE Q Credit 1.1: Indoor Air Quality Best Management Practices—Indoor Air Quality

Management Program

1

1

Measure, monitor, register, analyze data: indoor air quality for CAI program

IE Q Credit 1: Outdoor Air Delivery Monitoring

1

1

Measure, monitor, register, and analyze data: CO2 sensor network.

IE Q Credit 2: Increased Ventilation

1

1

Measure, monitor, register, analyze data: room by room fresh air ventilation rates are met

IE Q Credit 5: Indoor Chemical and Pollutant Source Control

1

1

Measure, monitor, register, analyze data: collected by electronic noses

IE Q Credit 6.1: Controllability of Systems—Lighting

1

1

Measure, monitor, register, analyze data: direct light sensors and solar radiation

IE Q Credit 6.2: Controllability of Systems—Thermal Comfort

1

1

Measure, monitor, register, analyze data: temperature, humidity, speed air, radiant temperature, alarms, problem identification

IE Q Credit 7.2: Thermal Comfort—Verification

1

1

Measure, monitor, register, analyze data: temperature sensors and various thermostats

 

Multidomo Metering® requires a standard automation system implemented in the building which will allow reading values of sensors to Metering®.

  Sign in   Recent Site Activity   Terms   Report Abuse   Print page  |  Powered by Google Sites