LEED is an internationally recognized green building certification system, providing third-party verification that a building or community was designed and built using strategies aimed at improving performance across all the metrics that matter most: energy savings, water efficiency, CO2 emissions reduction, improved indoor environmental quality, and stewardship of resources and sensitivity to their impacts.
Developed by the U.S. Green Building Council (USGBC), LEED provides building owners and operators a concise framework for identifying and implementing practical and measurable green building design, construction, operations and maintenance solutions
Contribution of Multidomo Metering® for LEED®EB-O&M certification
LEED®EB-O&M certifies that the work of operation and maintenance of the building are being sustainably. Multidomo Metering® contributes and can help you get up to 3 LEED® prerequisites that are required and between 15 and 50 LEED® points from 110 volunteers of LEED® (14%-45%), collecting data and providing information of different measurements (consumption, temperature, air quality).
|
Credit |
Min. Points |
Max. Points |
How |
|
SS Credit 6: Stormwater Quantity Control |
1 |
1 |
Measure, monitor, register, analyze data: rain and re-use |
|
WE Prerequisite 1: Minimum Indoor Plumbing Fixture and Fitting Efficiency |
R |
R |
Measure, monitor, register, and analyze data consumption: taps, sanitary, urinary, showers, batteries and landfills. |
|
WE Credit 1: Water Performance Measurement |
1 |
2 |
Measure, monitor, register, and analyze data consumption: garden irrigation, equipment and systems plumbing, cooling towers, hot water, process water. Total of the building and plot |
|
WE Credit 4: Cooling Tower Water Management |
1 |
2 |
Measure, monitor, register, analyze data: drip rates and disinfectants concentration, replenishment not potable water quantities |
|
EA Prerequisite 1: Energy Efficiency Best Management Practices—Planning,
Documentation and Opportunity Assessment |
R |
R |
Measure, monitor, register, analyze data: ASHRAE level I energy audit |
|
EA Prerequisite 2: Minimum Energy Efficiency Performance |
R |
R |
Measure, monitor, register, and analyze data: every building energy use. 12 months continuous measuring. |
|
EA Credit 1: Optimize Energy Efficiency Performance |
1 |
18 |
Measure, monitor, register, and analyze data: every building energy use. 12 months continuous measuring. |
|
EA Credit 2.1: Existing Building Commissioning—Investigation and Analysis |
2 |
2 |
Analysis and energy data use classification. Measure, record, and analyze data for energy auditing ASHRAE level II. |
|
EA Credit 2.3: Existing Building Commissioning—Ongoing Commissioning |
2 |
2 |
Measure, monitor, register, analyze data: systematic efficiency measurements and efficiency deviations |
|
EA Credit 3.2: Performance Measurement—System-Level Metering |
1 |
2 |
Measure, monitor, register, analyze data: permanently 40% - 80% total consumption for 2 years and for different building energy uses (mechanical systems and other uses) |
|
EA Credit 4: On-site and Off-site Renewable Energy |
1 |
16 |
Measure, monitor, register, analyze data: renewable energy produced or purchased by the building |
|
EA Credit 6: Emissions Reduction Reporting |
1 |
1 |
Measure, monitor, register, analyze data: reductions in emissions by renewable and energy efficiency |
|
IE Q Credit 1.1: Indoor Air Quality Best Management Practices—Indoor Air Quality Management Program |
1 |
1 |
Measure, monitor, register, analyze data: indoor air quality for CAI program |
|
IE Q Credit 1.2: Indoor Air Quality Best Management Practices—Outdoor Air
Delivery Monitoring |
1 |
1 |
Measure, monitor, register, and analyze data: CO2 sensor network. |
|
IE Q Credit 1.3: Indoor Air Quality Best Management Practices—Increased
Ventilation |
1 |
1 |
Measure, monitor, register, analyze data: room by room fresh air ventilation rates are met |
|
IE Q Credit 2.3: Occupant Comfort—Thermal Comfort Monitoring |
1 |
1 |
Measure, monitor, register, analyze data: temperature, humidity, speed air, radiant temperature, alarms, problem identification |
Contribution of Multidomo Metering® for LEED®NC and LEED®CI
LEED®NC and LEED®CI, certify respectively the buildings in new plant and great remodeling and the second indoor deployments whether new or renovations to existing buildings. Multidomo Metering® contributes and can help you get up to 2 LEED® prerequisites that are required and between 19 and 47 LEED® points from 110 volunteers of LEED® (14%-45%), collecting data and providing information of different measurements (consumption, temperature, air quality).
|
Credit |
Min. Points |
Max. Points |
How |
|
SS Credit 6.1: Stormwater Design—Quantity Control |
1 |
1 |
Measure, monitor, register, analyze data: rain and re-use |
|
SS Credit 6.2: Stormwater Design—Quality Control |
1 |
1 |
Measure, monitor, register, analyze data: water filtration from rain and re-use |
|
WE Prerequisite 1: Water Use Reduction |
R |
R |
Measure, monitor, register, and analyze data consumption: taps, sanitary, urinary, showers, batteries and landfills. |
|
WE Credit 1: Water Efficient Landscaping |
2 |
4 |
Measure, monitor, register, and analyze data consumption: garden irrigation. |
|
WE Credit 2: Innovative Wastewater Technologies |
2 |
2 |
Measure, monitor, register, analyze data: issued waste water and filter parameters |
|
WE Credit 3: Water Use Reduction |
2 |
4 |
Measure, monitor, register, and analyze data consumption: taps, sanitary, urinary, showers, batteries and landfills. |
|
EA Prerequisite 2: Minimum Energy Performance |
R |
R |
Measure, monitor, register, and analyze data: every building energy use. 12 months continuous measuring. |
|
EA Credit 1: Optimize Energy Performance |
1 |
19 |
Measure, monitor, register, and analyze data: every building energy use. 12 months continuous measuring. |
|
EA Credit 4: Green Power |
1 |
7 |
Measure, monitor, register, analyze data: renewable energy produced or purchased by the building |
|
EA Credit 5: Measurement and Verification |
3 |
3 |
Measure, follow, register, analyze data: 10 parameters IPMVP one year of operation |
|
IE Q Credit 1.1: Indoor Air Quality Best Management Practices—Indoor Air Quality
Management Program |
1 |
1 |
Measure, monitor, register, analyze data: indoor air quality for CAI program |
|
IE Q Credit 1: Outdoor Air Delivery Monitoring |
1 |
1 |
Measure, monitor, register, and analyze data: CO2 sensor network. |
|
IE Q Credit 2: Increased Ventilation |
1 |
1 |
Measure, monitor, register, analyze data: room by room fresh air ventilation rates are met |
|
IE Q Credit 5: Indoor Chemical and Pollutant Source Control |
1 |
1 |
Measure, monitor, register, analyze data: collected by electronic noses |
|
IE Q Credit 6.1: Controllability of Systems—Lighting |
1 |
1 |
Measure, monitor, register, analyze data: direct light sensors and solar radiation |
|
IE Q Credit 6.2: Controllability of Systems—Thermal Comfort |
1 |
1 |
Measure, monitor, register, analyze data: temperature, humidity, speed air, radiant temperature, alarms, problem identification |
|
IE Q Credit 7.2: Thermal Comfort—Verification |
1 |
1 |
Measure, monitor, register, analyze data: temperature sensors and various thermostats |
Multidomo Metering® requires a standard automation system implemented in the building which will allow reading values of sensors to Metering®. |